- 产品介绍
- 相关证书
- PDF下载
- 样品申请
电气特性
焦耳积分值I²t以下电气特性曲线说明了额定电压 以及15%功率因数时的总焦耳积分 值I²t。如施加的电压并非额定电压,可以乘以校正因数K求算实际的I²t。参阅图中工作电压Eg(RMS)与校正 因数K的函数关系。
35—800A
|
弧电压图中的曲线说明了15%功率因数时施加的工作电压Eg(RMS)与工作时熔断器上可能出现的峰值弧电压UL的函数关系。
1) 35-200A 2) 225-800A
|
|
尺寸

|
订购号码 |
A |
B |
C |
D |
E |
F |
G |
H |
|
FWH-35C-60C |
81.01 |
61.16 |
40.31 |
13.13 |
8.69 |
15.8 |
20.52 |
3.18 |
|
FWH-70C-100C |
92.23 |
72.27 |
53.01 |
13.16 |
8.76 |
19.05 |
25.4 |
3.18 |
|
FWH-125C-200C |
92.23 |
71.17 |
53.01 |
11.86 |
8.79 |
25.4 |
30.94 |
4.78 |
|
FWH-225C-400C |
110.31 |
78.28 |
53.01 |
19.07 |
10.34 |
25.4 |
38.1 |
6.35 |
|
FWH-450C-600C |
109.91 |
79.93 |
53.01 |
19.86 |
10.36 |
37.97 |
50.8 |
6.35 |
|
FWH-700C-800C |
160.41 |
106.7 |
53.01 |
33.02 |
13.46 |
50.8 |
63.5 |
9.53 |
单位:mm
1mm=0.0394in 1in=25.4mm
|
电气特性 |
订购信息 |
||||||
|
类型 |
额定电流 RMS(A) |
I²t(A²Sec) |
功率损耗 (w) |
产品代码 |
每包数量 (pcs) |
每包重量 (kg) |
|
|
弧前焦耳积分 |
500V 时的总焦耳积分值 |
||||||
|
FWH 500V |
35 |
34 |
150 |
8 |
FWH-35C |
5 |
0.32 |
|
40 |
76 |
320 |
7.5 |
FWH-40C |
|||
|
50 |
135 |
670 |
7.5 |
FWH-50C |
|||
|
60 |
210 |
900 |
9.9 |
FWH-60C |
|||
|
70 |
210 |
900 |
10.6 |
FWH-70C |
1 |
0.095 |
|
|
80 |
305 |
1400 |
12.7 |
FWH-80C |
|||
|
90 |
360 |
1600 |
15 |
FWH-90C |
|||
|
100 |
475 |
2000 |
17 |
FWH-100C |
|||
|
125 |
800 |
3500 |
25 |
FWH-125C |
0.149 |
||
|
150 |
1100 |
4600 |
30 |
FWH-150C |
|||
|
175 |
1450 |
6200 |
35 |
FWH-175C |
|||
|
200 |
1900 |
8500 |
40 |
FWH-200C |
|||
|
225 |
4600 |
23300 |
39 |
FWH-225C |
0.257 |
||
|
250 |
6300 |
32200 |
41 |
FWH-250C |
|||
|
275 |
7900 |
40300 |
46 |
FWH-275C |
|||
|
300 |
9800 |
49800 |
51 |
FWH-300C |
|||
|
325 |
13700 |
63800 |
53 |
FWH-325C |
|||
|
350 |
14500 |
72900 |
58 |
FWH-350C |
|||
|
400 |
19200 |
96700 |
65 |
FWH-400C |
|||
|
450 |
24700 |
127000 |
74 |
FWH-450C |
0.45 |
||
|
500 |
29200 |
149000 |
84 |
FWH-500C |
|||
|
600 |
41300 |
206000 |
108 |
FWH-600C |
|||
|
700 |
55000 |
298000 |
120 |
FWH-700C |
0.96 |
||
|
800 |
76200 |
409000 |
129 |
FWH-800C |
|||
1kg=2.2磅 1磅=0.45kg
· 交流分断容量200kA。(已获CCC认证以及UL认证)
· 直流分断容量50kA。(已获UL认证)
· 功率损耗为额定电流时的功率损耗值。
时间-电流曲线
预期电流(单位:安培RMS)
截断电流曲线
预期短路电流对称RMS